Hi Frits,
My soundcard is a Creative Audigy 2 ZS Pro
In Podium I can only run in two channel mode as follows…..
Podium audio manager status report
Log period: 25/05/2004 12:28:28 AM – 25/05/2004 12:28:28 AM
ASIO device: ASIO DirectX Driver
– Supported clock sources: Internal
– Current clock source: Internal
– Supported sample rates: 32000, 44100, 48000, 88200, 96000
– Current sample rate: 44100
– Input channels: 2 (11)
– Output channels: 2 (11)
– Input/Output latency, buffer size: 0/9000, 3000
– ASIO sample types: 16, 16
End of report
******************************************************************************
As I currently cannot use the 20 channels unless its 48Khz.
Podium audio manager status report
Log period: 25/05/2004 12:26:05 AM – 25/05/2004 12:26:05 AM
ASIO device: SB Audigy 2 ZS ASIO [B800]
– Supported clock sources: Internal
– Current clock source: Internal
– Supported sample rates: 48000
– Current sample rate: 44100
– Input channels: 20 (11111111111111111111)
– Output channels: 20 (11111111111111111111)
– Input/Output latency, buffer size: 0/0, 960
End of report
Podium complains and displays message “Could not start 44100 audio streaming”
>>>>> Will Podium support 48KHZ?
***************************************************************************************
Also in the Audio setup config screen if I press “Driver Setup” … Podium crashes.
*********************************
*** OK I got it working
Podium audio manager status report
Log period: 29/05/2004 11:16:45 PM – 29/05/2004 11:16:45 PM
ASIO device: SB Audigy 2 ZS ASIO [B800]
– Supported clock sources: Internal
– Current clock source: Internal
– Supported sample rates: 48000
– Current sample rate: 48000
– Input channels: 20 (11111111111111111111)
– Output channels: 20 (11111111111111111111)
– Input/Output latency, buffer size: 1060/960, 960
– ASIO sample types: 16, 16
End of report
**************************************
Its good if you start with a clean slate.
It appears that Podium fails to check that the current sample rate is still valid after changing driver.
Using ASIO DirectX Driver, sample rate is set to 44100. Changing to SB Audigy driver, the 44100 is not supported by the driver, which probably caused the problem you saw. I’ll check my code for this.
@Zynewave wrote:
It appears that Podium fails to check that the current sample rate is still valid after changing driver.
Using ASIO DirectX Driver, sample rate is set to 44100. Changing to SB Audigy driver, the 44100 is not supported by the driver, which probably caused the problem you saw. I’ll check my code for this.
I get that error with the demo – Audigy 2 Plat runs 48k in AISO but podium warns it cannot stream at 44.1 (latest demo)
Best regards,
Spe3d
:O)
First check that the default samplerate in the interfaces dialog is set to 48000. Furthermore when you want to work with arrangements you should set the samplerate in the arrangement properties dialog to 48000. The Freebees demo project are set to use 44100, so you need to change the samplerate to 48000 in the demo arrangements.
@Zynewave wrote:
First check that the default samplerate in the interfaces dialog is set to 48000. Furthermore when you want to work with arrangements you should set the samplerate in the arrangement properties dialog to 48000. The Freebees demo project are set to use 44100, so you need to change the samplerate to 48000 in the demo arrangements.
Cool, many thanks this is the issue solved 🙂
Best regards,
Spe3d
:O)
Hi Spe3d,,,, I was able to get the Freebies.pod project working at 44.1 by selecting the ASIO DirectX Driver from my driver list. Maybe the Freebies.pod has project settings which allow it to only work at 44.1..
anyway here is the report of my settings to get audio with the Freebies.pod project.
Podium audio manager status report
Log period: 20/06/2004 6:48:15 PM – 20/06/2004 6:49:57 PM
ASIO device: ASIO DirectX Driver
– Supported clock sources: Internal
– Current clock source: Internal
– Supported sample rates: 32000, 44100, 48000, 88200, 96000
– Current sample rate: 44100
– Input channels: 2 (11)
– Output channels: 2 (11)
– Input/Output latency, buffer size: 3000/9000, 3000
– ASIO sample types: 16, 16
ASIO driver status:
– ASIO sample position gaps: 1 (3000)
Audio stream buffer errors:
– Output buffer skip count: 1
End of report
**************************************
All my other .pod projects are at 48KHz using the
Audigy ZS ASIO [B800] Driver so I can use all 20 I/O’s available.
Switching between Sampling Rates I sometimes get the message “Could not start 44100 audio streaming” even though I know my project is 48KHz,,,,I just close Podium and restart it and then make the change.
I think improved Demos are on the cards.
*********************
EDIT:….. I see there is already a response,,,, I am so slow at typing.
Hi! Papawillow, 🙂
Many thanks for typing out your solution. I will investigate your workings too. 😉
Best regards,
Spe3d
:O)